• <tr id='gXNJ6G'><strong id='gXNJ6G'></strong><small id='gXNJ6G'></small><button id='gXNJ6G'></button><li id='gXNJ6G'><noscript id='gXNJ6G'><big id='gXNJ6G'></big><dt id='gXNJ6G'></dt></noscript></li></tr><ol id='gXNJ6G'><option id='gXNJ6G'><table id='gXNJ6G'><blockquote id='gXNJ6G'><tbody id='gXNJ6G'></tbody></blockquote></table></option></ol><u id='gXNJ6G'></u><kbd id='gXNJ6G'><kbd id='gXNJ6G'></kbd></kbd>

    <code id='gXNJ6G'><strong id='gXNJ6G'></strong></code>

    <fieldset id='gXNJ6G'></fieldset>
          <span id='gXNJ6G'></span>

              <ins id='gXNJ6G'></ins>
              <acronym id='gXNJ6G'><em id='gXNJ6G'></em><td id='gXNJ6G'><div id='gXNJ6G'></div></td></acronym><address id='gXNJ6G'><big id='gXNJ6G'><big id='gXNJ6G'></big><legend id='gXNJ6G'></legend></big></address>

              <i id='gXNJ6G'><div id='gXNJ6G'><ins id='gXNJ6G'></ins></div></i>
              <i id='gXNJ6G'></i>
            1. <dl id='gXNJ6G'></dl>
              1. <blockquote id='gXNJ6G'><q id='gXNJ6G'><noscript id='gXNJ6G'></noscript><dt id='gXNJ6G'></dt></q></blockquote><noframes id='gXNJ6G'><i id='gXNJ6G'></i>

                OFFICAL BLOG ÖÐÎÄ°æ | ENGLISH

                Customer service hotline : 400-600-5217      010-84917838

                Your current position£ºhomepage  

                brand£ºFLEXIM

                name£ºFLEXIM multifunctional ultrasonic flowmeter ADM7407/G704

                introduction£º

                With one or two flow channels and versatile electrical inputs and outputs, the FLUXUS ADM 7407 can optimally be configured to your application needs, measuring and handling a variety of process parameters.

                The FLUXUS ADM 7407 features a robust metal field housing. Its clamp-on flow transducers are simply mounted onto the pipe from the outside and are thus installed quickly, without any process interruption and without any production stop.

                Since the flowmeter's transducers are not in contact with the medium to be measured, they are not submitted to wear and tear. Transducers for the common pipe diameters (0,25 to 63 inches feet) and temperatures ranges (from -256°F to 750°F) as well as hazardous zones (ATEX and FM) are available.

                The measurement is pressure independent and can take place on pipes of almost any materials and on almost any liquid.

                • Features
                  ?Non-invasive measurement using the clamp-on technology for precise bi-directional, highly dynamic flow measurement
                  ?ATEX, IEC, FM approved transducers for hazardous areas available
                  ?Automatic loading of calibration data and transducer detection reduce set-up times and provide precise,long-term stable results
                  ?Transducers available for a wide range of inner pipe diameters (6...6500 mm) and fluid temperatures(-40...+400 °C)
                  ?Proven clamp-on technology, transducers resistant to dust and humidity
                  ?HybridTrek automatically switches between transit time and NoiseTrek mode of measurement when high particulate flows are encountered
                  ?User-friendly design
                • FLUXUS?/SUP> ADM 7407: liquid flow meter for permanent installations

                  Flow channels

                  1 or 2
                  Operating temperature range of transmitter 14 °F ... 140 °F
                  Degree of protection NEMA 4X
                  Available Hazardous Area Classification FM Class I, Div.2 or ATEX Zone 2 optional
                  Outputs A variety of combinations are available from the following:
                  current (0/4 mA ... 20 mA), voltage, frequency, pulse, alarm
                  Inputs Maximum 4, Available are: Temperature (PT 100 4-wire), current, voltage
                  Communication Protocol HART or ModBus RTU or RS485 or BACNet MS/TP
                  Media temperature -40°F ... 390°F (-270°F ... 750°F with High Temperature WaveInjector mounting fixture)
                  Pipe diameter range 1/4 inch ... 63 inches
                  Flow velocity range 0,03 ... 75 ft/sec
                  Calibrated accuracy* ?0.5% of reading ?0.03 ft/s
                  with field calibration**
                  ?1.0% of reading ?0.03 ft/s
                  with 5-point NIST calibration (factory standard)

                  * under reference conditions and with v > 0.49 ft/s
                  ** if reference uncertainty better than < 0.2%

                • Please call conasen hotline  4006005217 consulting ADM7407/G704 details!
                Site map©¦Legal Notice©¦Contact us
                ©2007 Beijing Conasen technology CO.,LTD All rights reserved

                Major Product Categories£ºLevel    Pressure    Flow    Temperature    Analysis    Display    Others

                Site Keywords£ºUE    FLOWLINE    MONITOR    NIVELCO    FLEXIM    SIKA    PRICISION DIGITAL